{"product_id":"votatec-weather-resistant-gfci-receptacle-15a-or-20a-tamper-resistant-self-test-led-indicator-white-or-black","title":"Votatec Weather-Resistant GFCI Receptacle – 15A or 20A, Tamper-Resistant, Self-Test, LED Indicator, White or Black","description":"\u003ch2\u003eVotatec Weather-Resistant GFCI Receptacle\u003c\/h2\u003e\n\u003cp\u003eProvide reliable ground-fault protection with the Votatec Weather-Resistant GFCI Receptacle. Available in 15A and 20A models, this self-testing receptacle monitors its protective function and uses LED indicators to communicate power, protection and end-of-life status.\u003c\/p\u003e\n\u003cp\u003eThe tamper-resistant shutters help prevent foreign objects from being inserted into the receptacle slots, while weather-resistant construction uses enhanced corrosion-resistant components for demanding moist and humid environments.\u003c\/p\u003e\n\u003cp\u003eChoose from \u003cstrong\u003e15A or 20A\u003c\/strong\u003e ratings and \u003cstrong\u003eWhite or Black\u003c\/strong\u003e finishes to match the electrical circuit and surrounding wiring devices.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround-fault protection:\u003c\/strong\u003e Trips when a ground-fault current of approximately 5mA is detected\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic self-test:\u003c\/strong\u003e Regularly checks the GFCI protection function for added safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous protection:\u003c\/strong\u003e Designed to detect and interrupt an actual ground fault, including during the self-test cycle\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTamper-resistant shutters:\u003c\/strong\u003e Help prevent foreign objects from reaching energized receptacle contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeather-resistant construction:\u003c\/strong\u003e Enhanced corrosion-resistant components provide improved durability in moist or humid environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED status indicators:\u003c\/strong\u003e Provide clear feedback on power, reset, fault and end-of-life conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast response:\u003c\/strong\u003e Ground-fault trip time of less than 25 milliseconds under specified conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLINE and LOAD terminals:\u003c\/strong\u003e May provide GFCI protection to compatible downstream receptacles when correctly wired\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable thermoplastic housing:\u003c\/strong\u003e Designed for strength, impact resistance and dependable operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e15A and 20A options:\u003c\/strong\u003e Select the appropriate configuration for the branch circuit and application\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo finish options:\u003c\/strong\u003e Available in White and Black\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus Listed:\u003c\/strong\u003e Evaluated to applicable Canadian and U.S. safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAvailable Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e15A – White\u003c\/li\u003e\n\u003cli\u003e15A – Black\u003c\/li\u003e\n\u003cli\u003e20A – White\u003c\/li\u003e\n\u003cli\u003e20A – Black\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLED Status Indicators\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGreen Indicator:\u003c\/strong\u003e The GFCI is powered, properly reset and operating normally.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRed Indicator:\u003c\/strong\u003e Indicates a fault condition or unsuccessful internal self-test. Follow the supplied instructions to test and reset the device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlashing Red Indicator:\u003c\/strong\u003e On supported models, a flashing red light indicates an end-of-life condition and the receptacle must be replaced.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e The LEDs are status indicators. They are not intended to illuminate the surrounding area as a night light.\u003c\/p\u003e\n\u003ch3\u003eTamper-Resistant Protection\u003c\/h3\u003e\n\u003cp\u003eBuilt-in safety shutters help block access to the internal energized contacts unless a compatible plug is inserted correctly. This feature helps reduce the risk of foreign objects being inserted into the receptacle slots.\u003c\/p\u003e\n\u003ch3\u003eWeather-Resistant Construction\u003c\/h3\u003e\n\u003cp\u003eWeather-resistant materials and corrosion-resistant components provide greater durability in moist, humid and temperature-changing environments than an ordinary indoor receptacle.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWeather resistant does not mean waterproof.\u003c\/strong\u003e When installed outdoors or in a wet location, the receptacle must be installed in a suitable electrical box with an approved weatherproof cover and gasket as required by applicable electrical codes.\u003c\/p\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBathrooms and powder rooms\u003c\/li\u003e\n\u003cli\u003eKitchens and laundry rooms\u003c\/li\u003e\n\u003cli\u003eGarages and workshops\u003c\/li\u003e\n\u003cli\u003eBasements and utility rooms\u003c\/li\u003e\n\u003cli\u003eCommercial washrooms\u003c\/li\u003e\n\u003cli\u003eCovered outdoor receptacle locations\u003c\/li\u003e\n\u003cli\u003ePatios, decks and exterior walls with an approved weatherproof enclosure\u003c\/li\u003e\n\u003cli\u003eOther locations requiring compatible GFCI protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVotatec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWeather-Resistant GFCI Receptacle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e15A Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYGB-094WR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e20A Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYGB-095WR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15A or 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125V AC, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1800W for 15A model; 2400W for 20A model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround-Fault Trip Threshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than 25ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Current Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDielectric Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14–12 AWG, subject to circuit and code requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLine, neutral and ground; optional load-side connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIn-wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGFCI, automatic self-test, tamper-resistant shutters and LED status indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWeather resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-35°C to 66°C (-31°F to 150.8°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.13 × 1.68 × 1.60 in. (10.5 × 4.28 × 4.07 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermoplastic and metal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAvailable Colours\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWhite and Black\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 943, UL 498 and CSA C22.2 No. 144.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Listing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ecULus Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eLINE and LOAD Connections\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eLINE terminals\u003c\/strong\u003e receive incoming power from the electrical panel. The GFCI receptacle itself is protected when the LINE terminals are wired correctly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLOAD terminals\u003c\/strong\u003e may be used to provide GFCI protection to compatible receptacles located downstream on the same circuit. Incorrect LINE\/LOAD wiring may prevent the GFCI from operating correctly.\u003c\/p\u003e\n\u003ch3\u003eTesting the GFCI\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eAfter installation, restore power at the circuit breaker.\u003c\/li\u003e\n\u003cli\u003ePress the \u003cstrong\u003eRESET\u003c\/strong\u003e button fully.\u003c\/li\u003e\n\u003cli\u003eConfirm that the green status indicator shows normal operation.\u003c\/li\u003e\n\u003cli\u003ePlug in a lamp or compatible test device and confirm that power is available.\u003c\/li\u003e\n\u003cli\u003ePress the \u003cstrong\u003eTEST\u003c\/strong\u003e button. The GFCI should trip and interrupt power.\u003c\/li\u003e\n\u003cli\u003ePress \u003cstrong\u003eRESET\u003c\/strong\u003e again to restore normal operation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTest the GFCI regularly according to the supplied instructions. Replace the device if it fails to trip, cannot be reset or displays an end-of-life warning.\u003c\/p\u003e\n\u003ch3\u003eBefore Ordering\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSelect the correct \u003cstrong\u003e15A or 20A\u003c\/strong\u003e model for the branch circuit.\u003c\/li\u003e\n\u003cli\u003eA 20A receptacle must be installed only on a compatible 20A circuit.\u003c\/li\u003e\n\u003cli\u003eWire size must comply with the circuit rating and applicable electrical code.\u003c\/li\u003e\n\u003cli\u003eThis device requires line, neutral and ground connections.\u003c\/li\u003e\n\u003cli\u003eDo not confuse weather resistance with waterproofing.\u003c\/li\u003e\n\u003cli\u003eOutdoor and wet-location installations require a compatible weatherproof box, cover and gasket.\u003c\/li\u003e\n\u003cli\u003eA wall plate and weatherproof cover are not included unless specifically stated in the selected package.\u003c\/li\u003e\n\u003cli\u003eConfirm applicable code requirements for the intended installation location.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Notice\u003c\/h3\u003e\n\u003cp\u003eTurn off power at the circuit breaker and verify that the circuit is de-energized before installation. Carefully identify the LINE and LOAD conductors before disconnecting the existing receptacle.\u003c\/p\u003e\n\u003cp\u003eIncorrect wiring can result in loss of GFCI protection. Installation must comply with applicable electrical codes and should be completed by a qualified electrician.\u003c\/p\u003e\n\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0021\/5420\/1135\/files\/GFCI-WR.pdf?v=1786132627\" target=\"_blank\" title=\"Votatec GFCI\" rel=\"noopener\"\u003e\u003cspan style=\"text-decoration: underline; color: rgb(43, 0, 255);\"\u003eDownload Product Spec Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/h2\u003e","brand":"Votatec","offers":[{"title":"15A \/ White","offer_id":44118131671110,"sku":"YGB-094WR \/ WH","price":16.0,"currency_code":"CAD","in_stock":true},{"title":"15A \/ Black","offer_id":44118131703878,"sku":"YGB-094WR \/ BK","price":16.0,"currency_code":"CAD","in_stock":true},{"title":"20A \/ White","offer_id":44118131736646,"sku":"YGB-095WR \/WH","price":16.0,"currency_code":"CAD","in_stock":true},{"title":"20A \/ Black","offer_id":44118131769414,"sku":"YGB-095WR \/BK","price":16.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0021\/5420\/1135\/files\/GFCI-094-2.jpg?v=1786133020","url":"https:\/\/canlightinginc.com\/products\/votatec-weather-resistant-gfci-receptacle-15a-or-20a-tamper-resistant-self-test-led-indicator-white-or-black","provider":"Can Lighting Inc.","version":"1.0","type":"link"}